Skip to main content

Section 1: silage, slurry and oil storage requirements

The storage of silage, slurry and solid livestock manure is controlled under the Water Resources (Control of Agricultural Pollution) (Wales) Regulations 2021 (the regulations) which has revoked and replaced The Water Resources (Control of Pollution) Silage and Slurry (Wales) Regulations 2010 (SSAFO).

These regulations set out the requirements for the design (capacity), construction and maintenance of storage facilities for silage, slurry and solid livestock manures.

They apply to all installations completed since September 1991.

They require you to notify Natural Resources Wales (NRW), in writing, at least 14 days before starting construction on a new, substantially enlarged or substantially re-constructed store. 

Natural Resources Wales have a preconstruction notification form for slurry and silage stores available online to help you provide the necessary information.

For further details, see Control of agricultural pollution regulations: guidance.

Oil storage 2016 changes

The requirements for agricultural oil storage were replaced by the Control of Pollution (Oil Storage) (Wales) Regulations 2016 in March 2016.

For further details, see Oil storage regulations.

These regulations cover all agricultural oil tanks, regardless of the date of construction.

Compliance standards for slurry and silage

All slurry and silage stores must be built to meet the capacity and construction standards as per the regulations summarised below. Exemptions to the construction requirements may apply to stores built, or in the process of being constructed, before 1991. Pre 1991 stores are only exempt from the construction standards if they do not pose a significant risk of causing a pollution and are not exempt from the capacity requirements.

Silage: baled and wrapped

  • Baled and wrapped or bagged silage must not be stored or opened within 10 metres of a watercourse.
  • If you use field silage sites to make or store field silage, or non-baled silage in large bags, for example ‘Ag bags’, you must notify NRW at least 14 days before you first use the site.

Silage clamps

  • The clamp base, effluent tank and drains must all be impermeable and resistant to attack from silage effluent. The base of the clamp must be designed and constructed in accordance with BS8007 or BS5502 Part 21.
  • Where walls are used, the base must extend beyond walls. All silage clamps must include a perimeter drainage channel connecting to an effluent tank.
  • All effluent must be collected and contained. The silage effluent tank capacity must be 20 litres/cubic metre of silo capacity – up to 1500 cubic metres, plus an additional 6.7 litres/cubic metre of silo capacity thereafter.
  • No part of this installation should be within 10 metres of a watercourse or land drains.
  • Clamps and drains must be capable of lasting for 20 years (with routine maintenance).
  • Below-ground effluent tanks must be capable of lasting for 20 years without maintenance. A certificate to confirm suitable design and construction of tank and clamp must be sent to NRW 14 days before construction begins. 
  • If the clamp has walls, they must be designed to BS5502 Part 22 and be resistant to attack from silage effluent. 

Slurry

  • Slurry is defined in the regulations as liquid or semi-liquid matter composed of excreta produced by livestock while in a yard or building.
  • Slurry definition includes parlour and yard washings, and any contaminated rainfall.
  • Separating clean rainwater from roofs and yards can reduce the slurry storage capacity required. 
  • No part of the system may be situated within 10 metres of a watercourse, where slurry could enter unless NRW has agreed, in writing, the location and additional measures to avoid pollution.

Slurry storage facilities requirements

  • Slurry stores, tanks, pipes, and channels must be impermeable. Where walls of the slurry store are not impermeable (e.g. weeping wall stores), the base must extend beyond the walls and have perimeter drains that connect to a slurry tank.
  • The base and walls of the slurry storage tank, any effluent tank, channels and reception pit, and the walls of any pipes, must be protected against corrosion, as described in BS 5502, Part 50 (1993).
  • Slurry storage tank and reception pit must be designed to BS 5502, Part 50 (1993).
  • The reception pit and associated channels must normally hold at least two days slurry production, including likely rainwater.
  • From 1 August 2024, you must provide a minimum of five or six months slurry storage, dependant on the type of slurry produced. (Ensure that any sloping sides and required freeboard are subtracted when calculating capacity.)
  • The slurry storage tank must be designed to have a minimum freeboard of 300mm, but earth banked stores must have a minimum 750mm freeboard to be maintained at all times.
  • All parts of the slurry storage system must be designed to last for 20 years with routine maintenance.
  • Any fixed drainage pipe from the slurry store must have 2 valves in series. These must be locked shut when not in use and for stores built since 2010 there must be at least 1 metre spacing between the valves.
  • You should ensure that you only use capable contractors or builders who understand and build in accordance with the SSAFO regulations and the Water Resources (Control of Agricultural Pollution) (Wales) Regulations 2021.
  • Silage effluent and slurry have been the source of serious pollution, often due to inadequate storage capacity or poor construction. Sufficient storage for silage effluent and slurry or manure is essential to prevent the need for spreading outside the growing season or during inappropriate weather and soil conditions.
  • Contact NRW as early as possible in the planning stage as they may be able to help save you time and money.
  • NRW can make sure you are complying with the regulations and minimising pollution risks in the most cost effective manner.
  • If any silage-making, or slurry storage system store poses a significant risk of pollution to surface or to ground waters, then NRW may issue a notice that requires you to make improvements.

Contact Natural Resources Wales (NRW) at:

Natural Resources Wales

Maes y Ffynnon
Penrhosgarnedd
Bangor
Gwynedd
LL57 2DW.

Telephone:

 0300 065 3000 (Monday to Friday, 8am to 6pm) 

Rydym yn croesawu galwadau a gohebiaeth yn Gymraeg / We welcome calls and correspondence in Welsh.

Section 2: environmental consents and licences

Natural Resources Wales (NRW), Local Authority (LA)

If an applicant proposes to install capital items which affect slurry or silage storage systems, or which could affect water flow they are advised to consult with Natural Resources Wales (NRW) and/ or their Local Authority (LA) as consent may be required to carry out the work. Applicants must do this before committing themselves to any proposed work and before they submit an application for grant assistance under this category. Please note that the NRW/LA may charge for the relevant permissions. Applicants are advised to contact the NRW/LA early enough to confirm if relevant permission(s) is required for the proposed work. If the NRW/LA confirms that permission is required, this must be supplied with the application. Applications cannot be processed until submission of any relevant permission(s) from the NRW/LA.

Planning consents, building regulations etc.

Applicants must obtain any necessary planning consent and abide by any other relevant statutory requirements. Applicants also need to check that their proposals do not break any bylaws, obstruct rights of way, affect oil or gas pipelines etc, and must avoid damaging the countryside or causing pollution. Applications cannot be processed unless any relevant permission(s) are received.

With regards to planning consents, applicants must include either the original planning approval documents or original receipt from the local planning authority that the planning application has been submitted. The payment of any grant will not be made until the original planning approval documents have been received and approved by Welsh Government.

Section 3: key requirements

If you are roofing over existing livestock feeding areas, livestock gathering areas and manure storage areas, you must demonstrate the whole area has a floor impermeable to water, slurry and silage effluent. e.g. concrete.  

All buildings, including slurry/manure stores and silage pits, should meet BS 5502 part 22:2013: designed to withstand the typical loads to which it will be exposed, based on its use and location. Where it is manufactured off-site for subsequent erection, the unit should be CE marked. For any structures that are not CE marked, the applicant will need to demonstrate compliance to BS 5502 part 22:2013 through the provision of structural calculations from suitably qualified engineers. 

The roof materials need to be resistant to corrosion and minimise condensation. To achieve this, the cladding should be constructed of fibre cement, or, alternatively, of insulated plastic-coated profiled steel where this can meet the corrosion resistance requirements. Purlins should be either treated timber or galvanised steel, with treated timber being preferable. Whilst painted steelwork is adequate, galvanised would be a better choice for longevity.

Section 4: list of eligible capital items

The grant covers capital investments in equipment and machinery that have been pre-identified to reduce the risk of causing harm to the environment. 

Slurry storage facilitates will only be supported if the roofs and yards associated with rain water entering the proposed storage facility or any existing storage are made good first, by demonstrating the existing infrastructure can achieve this or by requesting the items necessary to do so through the Infrastructure and Equipment – Nutrient Management category.

Where you produce slurry, if selected and to ensure eligibility for payment, you will be required to demonstrate how the grant will enable you to maintain compliance with the CoAPR requirements. 

If you do not meet CoAPR requirement, either prior to investment, or following investment with Infrastructure and Equipment – Nutrient Management w category support, you will not be eligible to apply for additional investment not associated with nutrient storage, e.g. slurry application equipment etc.

Item CodeInvestmentDescriptionTotal Score

 

Grant %

 Stores – Roofed or covered    

 

 

 

 

 

 

 

 

6404

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Covered manure stores 

 

 

 

 

 

 

 

 

 

 

 

Farmyard (solid) manure (other than slurry) store. Suitable for any bedding contaminated with any organic manure that can be stacked without slumping.

Must be covered (with a permanent roof) with a floor impermeable to water and slurry. The roofing including rainwater goods, flooring and retaining walls are eligible costs. The base of outside walls should be impermeable to stop polluted liquids getting out, or to prevent water getting in.

Liquid arising from the solid manure (slurry) must be contained within the store or diverted to an existing slurry store or reception pit. Where the liquid is not collected in an existing slurry store, the floor must slope towards the rear of the store.

Unless a SuDS approval specifies otherwise. clean water from the roof must be diverted to a clean water drain or rainwater harvesting system.

The design of the building must be suitable for organic manure that can be stacked. The external walls to be:

  • A minimum 3.6m high to enable stacking and efficient use of the supported area. 
  • Constructed of concrete.
  • Have to be constructed on three sides of the store. (Rear and both sides).

The front (access end) of the building to remain open without a wall or door, which are not eligible costs. Livestock gates can be erected across access to exclude livestock.

The size of the store should meet the manure storage requirements of the farm.

The area cannot be used for animal housing or storage.

Slurry storage facilities must be built to BS5502, details can be found at CIRIA report C759b - Livestock manure and silage storage Part 2 Design and construction.

 

485

 

 

 

 

 

 

 

 

 

 

 

 

 

50%

6416 Integral slurry storeReinforced PVC polyester coated fabric bag sitting within an earth structure.   Restrained at sides, fitted with gas vents.430

 

 

50%

6429Silage clampsA storage facility for silage with the clamp base, walls, effluent tank and drains being impermeable and resistant to attack from silage effluent. Built to BS5502.465

 

 

50%

 

 

 

 

 

 

 

 

6432

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slurry stores and associated reception pits 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stores, including slurry lagoons, concrete storage structures, above ground, concrete or steel stores suitable for storing slurry that is easy to pump.

Includes reception pits, stores for diluted slurry, such as run-off from dirty yards or solid manure stored on yards, the washings from buildings or yards used by livestock.

Reception pits should be built to hold at least two days’ slurry production and contaminated water, taking into account likely rainfall. 

Provide adequate access arrangements if tanks and pits are to be emptied by tractor-drawn slurry tankers. 

Roofing over new slurry store is only eligible under this item if the area is not used for livestock housing:

Where the store is intended to be covered with slats and roof for livestock housing, the underground store structure is eligible, but the installation of a slatted floor, roof and walls or gates to retain livestock are not eligible. In these instances, the store is required to have 5 months storage capacity for the housed livestock.

Any additional structures to aid the installation of slats, such as additional supporting walls or uprights within the slurry store are not eligible.

Where a roof is installed to keep rainwater from entering the store, the roof should only cover the area of the slurry store and cannot extend to other areas.

Where you intend to install a new store with slats for livestock housing, the quotes and subsequent invoice needs to clearly separate the costs of the store from the remaining investment.

Unless a SUDS approval specified otherwise, clean water from the roof must be diverted to a clean water drain or rainwater harvesting system.

Slurry storage facilities must be built to BS5502, details can be found at CIRIA report C759b - Livestock manure and silage storage Part 2 Design and construction.

For below ground slurry stores and lagoons, install appropriate safety fencing to prevent unauthorised access. The safety fence must be to Health and Safety Executive (HSE) specification in accordance with AIS9: Managing slurry on farms - AIS9 (rev1) (on hse.gov.uk).

The additional storage capacity provided by the new store must be sufficient to ensure the farm complies with the slurry storage capacity requirement of the Water Resources (Control of Agricultural Pollution) (Wales) Regulations 2021.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

428.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50%

6434

 

Systems for slurry management

 

Pumps, filters and control gear to manage level of slurry within reception pits.327.5

 

50%

6435Tanks for storage of lightly fouled water

Tanks for the storage of lightly fouled water and associated pipes and channels. May contain lightly contaminated run-off from lightly fouled concrete yards or from the dairy parlour collected separately from slurry.

You should ensure any liquid entering a lightly fouled water store for regular irrigation in closed periods meets the Regulatory definition for lightly fouled water. The liquid does not include drainage from yards or buildings used to house or feed livestock, liquids from weeping-wall stores, manure storage on hard standings, strainer boxes, slurry separators or silage effluent, all of which are rich in nitrogen.

428.75

 

 

50%

6439Under-floor transfer / flow channels

Under-floor transfer / flow channels to provide a means of transferring slurry from a place of collection to permanent storage. 

The base and walls of channels should be impermeable to stop polluted liquids getting out, or to prevent water getting in if they are built below ground. If slurry is emptied from channels to a reception pit through a sluice, the pit should be big enough to hold all the slurry that might be released.

Transfer channels must be built to BS5502, details can be found at CIRIA report C759b - Livestock manure and silage storage Part 2 Design and construction.

Under-floor channels, over which slatted floors are installed for animal housing / animal lying areas are not eligible for support.

Slatted covers for the purpose of enabling scraped slurry to enter the channel is eligible for support. 

Roofing over transfer channels is not eligible for support.

Photographs to be provided as part of the application to evidence location of new channel.

485

 

 

 

 

 

 

 

 

 

 

 

 

50%

 Covers and roofing   
6408

 

Fixed cover for an existing above ground slurry tank.

 

Reinforced PVC polyester coated fabric or tin cover. Normally these types of cover are attached to the sides of the tank with centre support pole and gas vents.

Rainwater falling onto the cover surface must be diverted away from store.

335

 

 

50%

6409

 

Fixed floating plastic membrane to cover a lagoon

A large plastic sheet with integral floats and gas vents.   The edges of the cover are secured to the lagoon banks ensuring that the structural integrity of the store is not impacted.

Rainwater falling onto the cover surface must be diverted away from store to a clean water drain.

302.50

 

 

50%

6410

 

Free floating plastic cover for above ground slurry stores.

 

Plastic sheet stretched over the store and tensioned around a plastic hoop, which floats on the surface.

Rainwater falling onto the cover surface must be diverted away from store to a clean water drain.

297.50

 

 

50%

6424Roofing over existing silage store

Roof structure, including supporting uprights and rainwater goods, impermeable to rainwater to cover existing silage store.

You must evidence that the whole area is impermeable to water, e.g. concrete.

An engineer’s report is required to confirm the silage stores structural integrity is maintained and the store continues to be compliant with CoAPR following erection of a roof. 

The area supported cannot be used as livestock housing. 

Unless a SuDS approval specifies otherwise, clean water from the roof must be diverted to a clean water drain or rain water harvesting system.

Does not include any walls, flooring or associated drainage.

Photographs to be provided as part of the application to evidence area to be supported.

225

 

 

 

 

 

40%

6425Roofing over existing slurry store

Roof structure, including supporting uprights and rainwater goods, impermeable to rainwater to cover existing slurry store.

You must evidence that the whole area is impermeable to water, e.g. concrete.

An engineer’s report is required to confirm the slurry stores structural integrity is maintained and the store continues to be compliant with CoAPR following erection of a roof. 

Roofing over an existing slurry store with slats for livestock housing is not eligible.

Unless a SuDS approval specifies otherwise, clean water from the roof must be diverted to a clean water drain or rain water harvesting system.

Does not include any walls, flooring or associated drainage.

Photographs to be provided as part of the application to evidence area to be supported.

225

 

 

 

40%

6426Roofing over existing manure store

Roof structure impermeable to rainwater, including supporting uprights, inclusive of guttering and downpipes, over previously uncovered existing manure storage area.

The store must be for farmyard (solid) manure and not slurry. The store would be suitable for any bedding contaminated with any organic manure that can be stacked without slumping.

The whole area under the roof will have an existing concrete floor that is impermeable to water, slurry or silage effluent.

The liquid run-off arising from solid manure stored on an impermeable surface is classed as slurry and must be contained appropriately. This slurry must be diverted to an existing slurry store or appropriate reception pit. If no store is currently available, all effluent must be contained within the facility.

Where a new reception pit is installed to collect the slurry, a minimum of 14 days’ notice must be submitted to NRW in writing before construction begins. Evidence of this notification will be required at claim stage.

The base of outside walls will be impermeable to stop polluted liquids getting out, or to prevent water getting in.

Unless a SuDS approval specifies otherwise, clean water from the roof must be diverted to a clean water drain or rainwater harvesting system.

The roofed area must remain as a manure storage area, the installation of a roof should not enable the area to be used for livestock housing.

Photographs to be provided as part of the application to evidence area to be supported.

225

 

 

 

 

 

 

40%

 

6427 

 

 

 

 

 

 

 

Roofing over existing feeding area 

 

 

 

 

 

 

Roof structure impermeable to rainwater, including supporting uprights, inclusive of guttering and downpipes, over previously uncovered existing livestock feeding area.

The whole area under the roof will have an existing concrete floor that is impermeable to water, slurry and silage effluent.

All slurry must be contained within the area as per current regulations and diverted into a suitably constructed store or appropriate reception tank.

Where a new reception pit or store is installed to collect the slurry, a minimum of 14 days’ notice must be submitted to Natural Resources Wales (NRW) in writing before construction begins.

Unless a SuDS approval specifies otherwise, clean water from the roof must be diverted to a clean water drain or rainwater harvesting system.

The feeding area must be enclosed to retain livestock with either walls or permanent barriers, including gates therein, where applicable. Areas which are considered temporary feeding areas will not be eligible.

The area should be used throughout the winter feeding period with livestock fed through permanent feeding arrangements. Where temporary or movable feeders are used, (e.g. to feed round bales) evidence will be required to demonstrate how the area relates to animal housing and access to water and that the area is a permanent feeding area.

Self-feeding within silage stores and/or silage stores used as feeding areas are ineligible under this item

Woodchip corrals and straw yards without a base impermeable to water and where resultant slurry is not contained are ineligible.

The roofed area has to remain as a feeding area, the installation of a roof should not enable the area to be used for livestock housing.

For livestock feeding areas which are not in use during the summer, photographs of the permanent feeding barriers and slurry collection location should be submitted along with a description of its winter use.

Photographs to be provided as part of the application to evidence area to be supported.

 

225

 

 

 

 

 

40%

6428Roofing over existing gathering area

Roof structure impermeable to rainwater, including supporting uprights, inclusive of guttering and downpipes, over previously uncovered existing livestock gathering area.

The whole area under the roof will have an existing concrete floor that is impermeable to water slurry and silage effluent.

All slurry must be contained within the area as per current regulations and diverted into a suitably constructed store or appropriate reception tank.

Where a new store or reception pit is installed to collect the slurry, a minimum of 14 days’ notice must be submitted to NRW in writing before construction begins. Evidence of this notice will be required at claim stage. 

Unless a SuDS approval specifies otherwise, clean water from the roof must be diverted to a clean water drain or rainwater harvesting system.

The gathering area must be enclosed to retain livestock with either walls or permanent barriers, including gates therein, where applicable. Areas which are considered temporary gathering areas will not be eligible.

The purpose of the gathering area must be demonstrated, e.g. collecting yard for milking parlour or access to a permanent handling system.

Areas where livestock travel infrequently between buildings or open yards are ineligible.

Areas where slurry is scraped from buildings to a store across open yards with no livestock activity are ineligible.

Gathering areas for livestock handling systems: The handling systems must be permanent and secured to the floor, roofs over mobile handling systems are ineligible.

Existing sheep or cattle handling systems are only eligible if all slurry, run-off and dirty water from washings produced are contained as per current regulatory requirements and diverted into a suitably constructed store or appropriate reception tank.

Where collection of all slurry, run-off and dirty water is not evidenced, the claim will not be valid. (e.g. a sheep handling system where currently there is no collection of run-off: The area will need to be contained and all slurry, run-off and dirty water diverted into a suitably constructed store or appropriate reception tank. A minimum of 14 days’ notice must be submitted to NRW in writing before construction of a store begins in all circumstances.

The roofed area must remain as a gathering area, the installation of a roof should not enable the area to be used for livestock housing.

Photographs to be provided as part of the application to evidence area to be supported.

224

 

 

 

 

 

 

 

 

 

40%

 Tanks and Spreading    
6402

 

Band Spreader or trailing shoe

 

Band spreader: The boom of the spreader has a number of hoses connected to it, distributing the slurry close to the ground in strips or bands. It is fed with slurry from a single pipe, thus relying on the pressure at each of the hose outlets to provide even distribution. Advanced systems use rotary distributors to proportion the slurry evenly to each outlet.

Trailing shoe is a similar configuration to the band spreader with a shoe added to each hose allowing the slurry to be deposited under the crop canopy onto the soil.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

 

 

390

 

 

 

40%

6405

 

Farmyard manure rotaspreader, rear discharge spreader or dual-purpose spreader. 

 

Rotaspreader: Side discharge spreader which features a cylindrical body and a pto-driven shaft fitted with flails running along the centre of the cylinder. As the rotor spins, the flails throw the solid manure out to the side.

Rear discharge spreader: Trailer body fitted with a moving floor or other mechanism which delivers solid manure to the rear of the spreader. The spreading mechanism can have either vertical or horizontal beaters, plus, in some cases, spinning discs.

Dual purpose spreader: Side discharge spreader with an open top V-shaped body capable of handling both slurry and solid manure. A fast spinning impeller or rotor, usually at the front of the spreader, throws the material from the side of the machine. The rotor is fed with material by an auger or other mechanism fitted in the base of the spreader and a sliding gate controls the flow rate of the material onto the rotor.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG) the item will not be supported.

The capacity of the item needs to be appropriate to the size of holding and volume of manure produced.

307.5

 

 

 

 

 

40%

6415Injector (Slurry)

Slurry is injected under the soil surface. There are various types of injector but each fit into one of two categories: either open slot shallow injection, up to 50 mm deep; or deep injection over 150 mm deep.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

430

 

 

 

 

40%

6417Irrigator

This is a self-travelling machine with flexible or reeled-in hoses usually fed from a network of underground pipes, with a centrifugal or positive displacement pump, situated near the slurry store.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

270

 

 

 

 

40%

6419

 

Pumped tanker plus Band Spreader or trailing shoe.

 

Pumped tanker: The slurry is pumped into and from the tanker using a slurry pump, either a centrifugal (e.g. impeller type) or positive displacement (e.g. lobe type) pump.   

Band Spreader: The boom of the spreader has a number of hoses connected to it, distributing the slurry close to the ground in strips or bands. It is fed with slurry from a single pipe, thus relying on the pressure at each of the hose outlets to provide even distribution. Advanced systems use rotary distributors to proportion the slurry evenly to each outlet. Trailing Shoe: Has similar configuration to the band spreader, but with a shoe added to each hose allowing the slurry to be deposited under the crop canopy onto the soil. If applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

Capacity of the item needs to be appropriate to the size of holding and volume of slurry produced.

341.25

 

 

 

 

 

 

 

 

 

40%

6436

Umbilical hose plus Band Spreader or trailing shoe

 

The slurry is fed by a drag hose to the distribution system fitted to the tractor; the hose is supplied with slurry usually direct from the slurry store by a centrifugal or positive displacement pump.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

 

375

 

 

 

 

40%

6437Umbilical hose plus Injector (Slurry)

The slurry is fed by a drag hose to the distribution system fitted to the tractor; the hose is supplied with slurry usually direct from the slurry store by a centrifugal or positive displacement pump.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

 

395

 

 

 

 

 

40%

6438Umbilical hose plus Irrigator 

The slurry is fed by a drag hose to the distribution system fitted to the tractor; the hose is supplied with slurry usually direct from the slurry store by a centrifugal or positive displacement pump.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

 

 

315

 

 

 

 

 

40%

6440

 

Vacuum tanker plus Band Spreader or Trailing Shoe 

Vacuum tanker: Slurry is sucked into the tanker by using an air pump to evacuate the air from the tank to create a vacuum; the tanker is emptied using the air pump to pressurise the tanker, so forcing the slurry out. 

Band Spreader: The boom of the spreader has a number of hoses connected to it, distributing the slurry close to the ground in strips or bands. It is fed with slurry from a single pipe, thus relying on the pressure at each of the hose outlets to provide even distribution. Advanced systems use rotary distributors to proportion the slurry evenly to each outlet.

Trailing Shoe: Has similar configuration to the band spreader, but with a shoe added to each hose allowing the slurry to be deposited under the crop canopy onto the soil.

If the applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

The capacity of the item needs to be appropriate to the size of holding and volume of slurry produced.

 

341.25

 

 

40%

6441Vacuum tanker plus Injector (Slurry)

Slurry is sucked into the tanker by using an air pump to evacuate the air from the tank to create a vacuum; the tanker is emptied using the air pump to pressurise the tanker, so forcing the slurry out. 

Injector: Slurry is injected under the soil surface. There are various types of injector but each fit into one of two categories: either open slot shallow injection, up to 50 mm deep; or deep injection over 150 mm deep.

If applicant has previously been supported to purchase this item. (via NMIS or SPG or Small Grant - Efficiency) the item will not be supported.

The capacity of the item needs to be appropriate to the size of holding and volume of slurry produced.

 

361.25

 

 

 

 

 

 

 

 

40%

6442Variable rate controller for sprayers and fertiliser spreadersAn electronic device to connect to an existing sprayer or fertiliser spreader for the purposes of variable rate application. The regulation system will work from either a pressure or a flow sensor and provide information on forward speed, application rate, total and partial area, total and partial volume applied, boom and section status and pressure, flow rate and tank level. 440

 

 

 

40%

 Chemical/Pesticide/Fuel oil storage   
6403Storage area for Chemicals 

Secure (lockable) bunded building or storage unit with suitable drainage to collect spillage. Frost protection. Possibly linked with filling/wash-down pad.

The size of the store must be appropriate to the requirements of the farm.

80

 

40%

 

6411

 

 

 

Fuel tanks and bunds  

 

 

 

Storage tank and associated pipe-work. The installed system must comply with the requirements of the Control of Pollution (Oil Storage) (Wales) Regulations 2016 The storage tank must be fit for purpose and provided with secondary containment (usually a bund) which can contain no less than 110% of the contents of the tank. 

The Regulations also contain specifications regarding fill points, dispensing equipment and overfill pipework which must be complied with. The materials for the tank and bund must be impermeable to the oil stored in them.

80

 

 

 

 

40%

 Other General    
6401Air ScrubbersMulti-pollutant scrubbers for removal of ammonia, odour, and particulate matter from livestock housing.330

 

40%

6406Field nurse tankUsed to transport various agricultural chemicals and liquids to the point of application.380

 

40%

6407First-flush rainwater diverters/downpipe filtersFirst-flush rainwater diverters/downpipe filters.300

 

40%

6412GPS and flow systems for slurry applicationSlurry flow meter, cab display/controller and GPS system.445

 

40%

6413GPS and equipment for precision farmingA standalone GPS unit with automatic field boundary measurement and field recognition. It should have a minimum capability of straight and curved guidance modes with the ability to print maps.445

 

 

40%

6414Hand held gas detectorPortable gas monitors which can aid farmers in staying safe while working around slurry. Gas monitors which monitor up to 4 gases - Oxygen, Carbon Monoxide, Methane and Hydrogen Sulphide. 75

 

 

40%

6418Livestock yard renewal and underground drainage pipework

Livestock yard renewal and underground drainage pipework for existing livestock feeding or livestock gathering areas. (New livestock yards are not eligible).

Only areas with a previously impermeable surface that required renewal are eligible. Area would have been a concrete floor which requires renewal.

Slurry from the yard must be diverted to a slurry store or reception pit.

Photographs to be provided as part of the application to evidence current condition of area to be supported.

240

 

 

 

40%

6420Pumps (Slurry)High pressure slurry pumps for use with umbilical hose. Centrifugal or Positive displacement. 260

 

40%

6421Rain Water harvesting and filtering equipment. (Above ground).

Rain water harvesting and filtering systems, comprising: 

Above ground tank. 

Filtration system and associated taps and fittings. 

Minimum tank size of 10,000 litres. 

Entry filtration system. (where more than one tank is installed and linked, only one entry filtration system is required). 

Overflow diverted to a clean water drain. 

Water used for cleaning, drinking, washing or storage for firefighting. Installed tank connected to a suitable water usage system. 

Water harvested from agricultural buildings and used for farm purposes.

 

 

 

150

 

 

 

 

40%

6422Rain Water harvesting and filtering equipment. (Below ground).

Rain water harvesting system, comprising: 

Below ground tank. 

A minimum tank size 20,000 litres. 

Filtration system and associated connectors and fittings. 

Water pump. 

UV filter. 

Entry filtration system. 

Overflow diverted to a clean water drain. 

Water used for cleaning, drinking or washing, installed tank connected to a suitable water usage system. 

Water harvested from agricultural buildings and used for farm purposes.

160

 

 

 

 

 

40%

6423Silage pusher-robotic Robotic system with intelligent software and programmable for the intended feed passage. The equipment should have the capability to detect the distance from the feed barrier along with the amount of feed in the passage.170

 

 

40%

6430Slurry scraping systems

Slurry scraping system able to run automatically. Can be electric slurry scraping system to replace a tractor using hydraulic drive or rope/chain winch scraping system, or a robotic slurry pusher/collector.

Slurry must be diverted to a collection channel or store.

215

 

 

 

40%

6431Slurry separator and equipmentSlurry pump and separator unit to separate liquid from the fibre fraction in animal slurries.280

 

50%

6433Sprayer filling/wash-down padBunded and/or covered concrete pad to contain spillage/wash-down water from crop sprayer. 130

 

40%